Jökull

Ataaseq assigiiaat ilaat

Jökull - 01.12.1987, Qupperneq 8

Jökull - 01.12.1987, Qupperneq 8
compositions. This may either be due to equilibration in the basalt sheet intrusions or that the same alteration minerals form in the acid and basaltic volcanics despite the difference in their composition. Gas geothermometers developed by D’Amore and Panichi (1980), Arnórsson and Gunnlaugsson (1985) and Arnórsson (1987) have been used to estimate subsurface temperatures in the Torfajökull field (Table 3). The correlation between the results of individual geother- mometers is shown in Fig. 2. C02-temperatures lie most- ly in the range 240-290°C. C02-N2-temperatures cover a larger range and towards lower temperatures. The steam samples giving low C02-N2-temperatures contain high nitrogen concentrations. These low temperatures can, therefore, be attributed to atmospheric contam- ination of the steam samples or partial condensation of the steam in cold water. The steam heated water would be degassed in the process, thus adding N2 to the remain- ing steam phase. Geothermometry temperatures obtained from the TABLE 3. Results on the gas geothermometry and steam condensation in the upflow of the Torfajökull field. Geothermometry temperatures % steam cond. Sample no. n o H2S h2 co2-h2 co2-n2 Ab Zc zbd 11 240 (225) 169 169 122 213 231 47 31 12 273 (278) 241 259 250 287 352 -59 -16 13 287 (283) 227 264 245 277 292 26 12 14 240 (194) 220 230 227 179 296 74 64 15 246 (193) 215 236 234 177 326 78 70 16 257 (257) 232 246 242 256 334 -4 -1 17 236 (181) 200 135 <100 168 151 76 69 18 246 (206) 221 274 299 190 392 73 61 19 265 (264) 212 249 240 261 318 8 4 20 253 (256) 223 256 262 259 371 -24 -8 21 265 (266) 231 266 269 265 395 -4 -1 22 332 (316) 285 301 261 300 372 71 45 23 304 (299) 280 288 270 294 (400) 31 13 24 272 (143) 238 255 245 137 344 95 93 25 269 (247) 217 256 250 228 322 66 47 26 249 (178) 249 236 231 165 325 84 79 27 256 (239) 218 238 229 224 323 54 36 28 276 (271) 226 250 231 262 314 33 16 29 281 (237) 242 263 249 212 338 84 73 30 293 (247) 230 267 244 221 310 88 77 31 247 (203) 224 223 210 186 299 75 64 32 275 (276) 215 244 222 278 293 -13 -4 33 246 (238) 235 249 256 228 360 33 19 34 281 (280) 209 222 179 278 246 9 4 35 280 (278) 228 238 207 277 287 7 3 36 344 (336) 277° 284° 259° 326 194 50 23 37 358 (337) 277° 292° 265° 319 197 75 48 a Values in parenthesis indicate C02-temperatures corrected for condensation according to Zb. bGeothermom- eter of D’Amore and Panichi (1980). 'Assumes conductive heat loss. dAssumes mixing of 100°C steam with 5°C water. Tunctions corresponding with saline waters and waters above 300°C were used (see Arnórsson and Gunnlaugsson 1985). Sample locations are shown in Fig. 1. Analyses of samples 11-24 are given by Arnórsson and Gunnlaugsson (1985), Table 6, in the same sequence as here. 6
Qupperneq 1
Qupperneq 2
Qupperneq 3
Qupperneq 4
Qupperneq 5
Qupperneq 6
Qupperneq 7
Qupperneq 8
Qupperneq 9
Qupperneq 10
Qupperneq 11
Qupperneq 12
Qupperneq 13
Qupperneq 14
Qupperneq 15
Qupperneq 16
Qupperneq 17
Qupperneq 18
Qupperneq 19
Qupperneq 20
Qupperneq 21
Qupperneq 22
Qupperneq 23
Qupperneq 24
Qupperneq 25
Qupperneq 26
Qupperneq 27
Qupperneq 28
Qupperneq 29
Qupperneq 30
Qupperneq 31
Qupperneq 32
Qupperneq 33
Qupperneq 34
Qupperneq 35
Qupperneq 36
Qupperneq 37
Qupperneq 38
Qupperneq 39
Qupperneq 40
Qupperneq 41
Qupperneq 42
Qupperneq 43
Qupperneq 44
Qupperneq 45
Qupperneq 46
Qupperneq 47
Qupperneq 48
Qupperneq 49
Qupperneq 50
Qupperneq 51
Qupperneq 52
Qupperneq 53
Qupperneq 54
Qupperneq 55
Qupperneq 56
Qupperneq 57
Qupperneq 58
Qupperneq 59
Qupperneq 60
Qupperneq 61
Qupperneq 62
Qupperneq 63
Qupperneq 64
Qupperneq 65
Qupperneq 66
Qupperneq 67
Qupperneq 68
Qupperneq 69
Qupperneq 70
Qupperneq 71
Qupperneq 72
Qupperneq 73
Qupperneq 74
Qupperneq 75
Qupperneq 76
Qupperneq 77
Qupperneq 78
Qupperneq 79
Qupperneq 80
Qupperneq 81
Qupperneq 82
Qupperneq 83
Qupperneq 84
Qupperneq 85
Qupperneq 86
Qupperneq 87
Qupperneq 88
Qupperneq 89
Qupperneq 90
Qupperneq 91
Qupperneq 92
Qupperneq 93
Qupperneq 94
Qupperneq 95
Qupperneq 96
Qupperneq 97
Qupperneq 98
Qupperneq 99
Qupperneq 100
Qupperneq 101
Qupperneq 102
Qupperneq 103
Qupperneq 104
Qupperneq 105
Qupperneq 106
Qupperneq 107
Qupperneq 108
Qupperneq 109
Qupperneq 110
Qupperneq 111
Qupperneq 112
Qupperneq 113
Qupperneq 114
Qupperneq 115
Qupperneq 116

x

Jökull

Direct Links

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.