Jökull


Jökull - 01.12.1987, Side 29

Jökull - 01.12.1987, Side 29
Fig. 18. The conceptual model of the Leirbotnar and Suðurhlíðar geothermal fields. — Hugmyndalíkan af jarðhitasvœðinu við Kröflu. (Fig. 18), 2) quantify the natural mass and the heat flow in the reservoir, 3) verify the transmissivity values ob- tained from the analysis of injection test data 4) estimate the generating capacity of the field, and 5) predict on a well-by-well basis the future field performance for al- ternative field development plans including the rein- jection of waste fluid. The Krafla modeling has been described extensively by Bödvarsson, et al. (1984a, b, c) and Pruess, et al. (1984). Their results are summarized below. The natural state model developed reproduced well the observed pressure and temperature data for the field. The model consisted of a vertical cross section which included both Leirbotnar and Suðurhlíðar (Fig. 18). The simulation model is in agreement with the assumption that the reservoir system is controlled by two upflow zones, one at Hveragil and the other close to the eastern border of Suðurhlíðar. The lower reservoir in Leirbotnar and the Suðurhlíðar one are two phase with average vapour saturation of 10-20 % (volumetric) in the fracture sys- tem. The porosity of the reservoir rock was assumed to be 5%. The permeability of the reservoir is 1-4 millidar- cy with an average of 2.0 md. The permeability seems to be controlled by vertical fractures as better match was obtained by allowing for higher vertical than horizontal permeability. The permeability of the upflow channels at Hveragil and Suðurhlíðar is estimated as 30 md. Fluids from the upflow channel in Suðurhlíðar recharge the reservoir at an estimated rate of 10 kg/s. The two phase fluid mixture flows laterally along a highly perme- able fracture zone at a depth of 1 km and mixes with the upflow at Hveragil. The natural fluid flows are assumed highest at Hveragil where 8 kg/s of steam are discharged to the surface fumaroles. The remainder of the ascend- ing fluid (13 kg/s) recharges the upper Leirbotnar reser- voir. Several models were developed to estimate the gener- ating capacity of the reservoir and to predict its future behaviour. In the most simple case a lumped parameter model was used, but distributed parameter models and a quasi three-dimensional model were also applied in or- der to get more reliable estimates. All were based on the natural state model. The results obtained indicated that the generating capacities of Leirbotnar and Suðurhlíðar are 30 and 20 MWe for 30 years, respectively. Future exploitation will give rise to extended vapor zones in the reservoir. Fluid enthalpy of production wells will rise with time and reach dry steam conditions as the reser- voir is depleted. The calculated flow rate decline for individual wells is generally low or of the order of 1-4% per year. Reinjection is predicted to change the future behaviour of the wells. In the short term (few years) the effect will be small, but when extended single phase steam zones have formed (after 10 years) reinjection will improve deliverabilities. Furthermore, it is possible that reinjection could create single-phase liquid condition in parts of the fracture system. This would increase the fluid pressure considerably and increase the mass flow rate of the production wells. The quasi three-dimensional model used to predict the future behaviour of the Krafla reservoir was cali- brated by matching the flow histories (mass flow and enthalpy) of wells that had been discharged for 1-6 years. This relatively short period influences the reliabil- ity of the predictions of the model. So far all observa- tions seem to be in agreement with the model, and for instance pressure build-up tests in wells in Leirbotnar and Suðurhlíðar in the summer of 1984 showed pressure drawdown in the reservoir close to predicted values (Sigurðsson, et al. 1985). CONCLUSIONS The Krafla geothermal area covers about 15 km2, but only 3-4 km2 divided between three well fields have been exploited so far. The production characteristics of the three well fields differ widely. The transmissivity is generally of the order 1-4 Dm. The enthalpy of the well discharges is high in most parts of the fields thus render- ing their exploitation efficient. The utilization of parts of the area (northern Leirbotnar and the western flanks of Mt. Krafla) has been greatly hampered by the intrusion of magmatic gases into the geothermal system causing blocking of wells by deposits and damages by corrosion. There are signs now (1986) that such effects are dimin- 27
Side 1
Side 2
Side 3
Side 4
Side 5
Side 6
Side 7
Side 8
Side 9
Side 10
Side 11
Side 12
Side 13
Side 14
Side 15
Side 16
Side 17
Side 18
Side 19
Side 20
Side 21
Side 22
Side 23
Side 24
Side 25
Side 26
Side 27
Side 28
Side 29
Side 30
Side 31
Side 32
Side 33
Side 34
Side 35
Side 36
Side 37
Side 38
Side 39
Side 40
Side 41
Side 42
Side 43
Side 44
Side 45
Side 46
Side 47
Side 48
Side 49
Side 50
Side 51
Side 52
Side 53
Side 54
Side 55
Side 56
Side 57
Side 58
Side 59
Side 60
Side 61
Side 62
Side 63
Side 64
Side 65
Side 66
Side 67
Side 68
Side 69
Side 70
Side 71
Side 72
Side 73
Side 74
Side 75
Side 76
Side 77
Side 78
Side 79
Side 80
Side 81
Side 82
Side 83
Side 84
Side 85
Side 86
Side 87
Side 88
Side 89
Side 90
Side 91
Side 92
Side 93
Side 94
Side 95
Side 96
Side 97
Side 98
Side 99
Side 100
Side 101
Side 102
Side 103
Side 104
Side 105
Side 106
Side 107
Side 108
Side 109
Side 110
Side 111
Side 112
Side 113
Side 114
Side 115
Side 116

x

Jökull

Direkte link

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.