Jökull

Ataaseq assigiiaat ilaat

Jökull - 01.12.1987, Qupperneq 38

Jökull - 01.12.1987, Qupperneq 38
the Krísuvík field indicate that it is meteoric (Árnason, 1976) as is, in fact, the case for geothermal waters in general. Unboiled and undegassed geothermal water would, therefore, be expected to have the same N2 con- centration as surface water, 0.71 mmoles/kg at equilib- rium, if its temperature was 5°C. Geothermal steam formed by extensive boiling of heated meteoric water Fig. 4. N2 concentrations and N2/Ar ratios in individual samples of fumarole steam from the Krísuvík field. The solid curves show how steam derived from water with N2/Ar = 37, 0.71 mmoles/kg of N2 and at 250°C and 300°C, as indicated, changes its N2 content and N2/Ar ratio upon atmospheric contamination. The dotted line shows changes in N2/Ar ratios and N2 concentrations during adiabatic boiling of 300°C water. — Styrkur N2 og N2IAr hlutföll í einstökum sýnum af gufu á Krísuvíkurs- vœði. Heildregnu ferlarnir sýna hvernig gufa breytir N2 styrk sínum og N2/Ar hlutfalli við blöndun við andrúms- loft og var þá gert ráðfyrir að þessi gufa vœri mynduð við innrœna suðu á 250°C og 300°C vatni í 100°C og að upphafsstyrkur N2 í þessu vatni hafi verið 0.71 mmól/kg og NJAr hlutfallið = 37. Punktalínan sýnir hvernig N2/Ar hlutfall og N2 styrkur breytast við mismikla inn- rœna suðu á 300°C vatni. would be expected to possess N2/Ar ratios similar to that of surface water in equilibrium with the atmosphere (37). Steam samples with lower N2/Ar ratios could, of course, form by an extraneous supply of Ar. However, partial degassing would also produce low N2/Ar water and later extensive boiling of this water would give rise to secondary steam with N2/Ar ratios of less than 37. One fumarole at Kóngsnáman in the Sveifluháls area was sampled 7 times in the period 1981-1985 (Table 3). The steam composition is very similar for C02 and H2S in all the samples. The less soluble gases, H2 and CH4, show some variation and there is a strong positive corre- lation between the two (R2 = 0.87) suggesting that this variation is due to either the presence of variable amount of equilibrium steam in the underlying reservoir or that partial, but variable, steam separation occurs during boiling. Variations in 02, N2 and Ar concentra- tions in the samples can mostly be explained by variable atmospheric contamination. TABLE 3. Repeated analysis of a fumarole in Kóngsnáman (mmoles/kg steam) Date of sampling C02 h2s H2 °2 CH4 N2 Ar 81-10-10 282.2 39.20 7.67 0, .68 0. ,088 8.06 0.128 81-10-13 318.9 42.40 9.44 0. ,32 0. .092 5.74 0.167 81-10-16 320.5 43.22 8.41 0. .03 0. .097 1.25 0.042 81-10-16 295.1 41.30 8.22 0. .05 0. .106 1 .45 0.049 84-07-06 284.4 42.77 18.98 0, .00 0. .193 3.93 0.177 84-07-24 318.2 39.03 12.12 0. .00 0. .102 76.01 1.020 85-12-27 294.9 41 .42 11.33 0 .02 0. .128 2.29 0.062 EVALUATION OF CONDENSATION IN UPFLOW ZONES Procedure The C02 and N2 concentrations in the fumarole steam at Krísuvík has been used to estimate the amount of steam condensation in the upflow zones. The condensa- tion is envisaged to occur by one of two processes or a combination of them. One process involves condensa- tion by conductive heat loss and the other condensation of the ascending steam in cooler groundwater or surface water. It is not possible to separate the effects of the two condensation processes. Estimation is only possible for each process separately. Several simplifying assump- tions are made for the estimation of the amount of steam condensation. They are: (1) Boiling is adiabatic to the point of mixing or conduc- tive heat loss. 36
Qupperneq 1
Qupperneq 2
Qupperneq 3
Qupperneq 4
Qupperneq 5
Qupperneq 6
Qupperneq 7
Qupperneq 8
Qupperneq 9
Qupperneq 10
Qupperneq 11
Qupperneq 12
Qupperneq 13
Qupperneq 14
Qupperneq 15
Qupperneq 16
Qupperneq 17
Qupperneq 18
Qupperneq 19
Qupperneq 20
Qupperneq 21
Qupperneq 22
Qupperneq 23
Qupperneq 24
Qupperneq 25
Qupperneq 26
Qupperneq 27
Qupperneq 28
Qupperneq 29
Qupperneq 30
Qupperneq 31
Qupperneq 32
Qupperneq 33
Qupperneq 34
Qupperneq 35
Qupperneq 36
Qupperneq 37
Qupperneq 38
Qupperneq 39
Qupperneq 40
Qupperneq 41
Qupperneq 42
Qupperneq 43
Qupperneq 44
Qupperneq 45
Qupperneq 46
Qupperneq 47
Qupperneq 48
Qupperneq 49
Qupperneq 50
Qupperneq 51
Qupperneq 52
Qupperneq 53
Qupperneq 54
Qupperneq 55
Qupperneq 56
Qupperneq 57
Qupperneq 58
Qupperneq 59
Qupperneq 60
Qupperneq 61
Qupperneq 62
Qupperneq 63
Qupperneq 64
Qupperneq 65
Qupperneq 66
Qupperneq 67
Qupperneq 68
Qupperneq 69
Qupperneq 70
Qupperneq 71
Qupperneq 72
Qupperneq 73
Qupperneq 74
Qupperneq 75
Qupperneq 76
Qupperneq 77
Qupperneq 78
Qupperneq 79
Qupperneq 80
Qupperneq 81
Qupperneq 82
Qupperneq 83
Qupperneq 84
Qupperneq 85
Qupperneq 86
Qupperneq 87
Qupperneq 88
Qupperneq 89
Qupperneq 90
Qupperneq 91
Qupperneq 92
Qupperneq 93
Qupperneq 94
Qupperneq 95
Qupperneq 96
Qupperneq 97
Qupperneq 98
Qupperneq 99
Qupperneq 100
Qupperneq 101
Qupperneq 102
Qupperneq 103
Qupperneq 104
Qupperneq 105
Qupperneq 106
Qupperneq 107
Qupperneq 108
Qupperneq 109
Qupperneq 110
Qupperneq 111
Qupperneq 112
Qupperneq 113
Qupperneq 114
Qupperneq 115
Qupperneq 116

x

Jökull

Direct Links

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.