Jökull


Jökull - 01.12.1987, Síða 47

Jökull - 01.12.1987, Síða 47
atures obtained from the gas geothermometers of Nehr- ing and D’Amore (1984). The geothermometers of Nehring and D’Amore (1984) constitute a product of C02 and H2 on one hand and C02 and H2S on the other. By reference to theoretical considerations of chemical equilibria in open systems, like geothermal systems, one would expect that the concentrations of each of the three gases considered would depend on temperature alone (Arnórsson etal., 1983) as the Cerro Prieto data indeed show. The C02/H2 ratios are lowest in the northeasternmost part of the Sveifluháls area, around the southern shore of Lake Kleifarvatn (Fig. 1). In the only fumarole sam- ple from this part of the Sveifluháls area (No. 8 in Table 1) this is due to elevated H2 concentration. Presumably this is also the case for gas samples from hot pools and from Lake Kleifarvatn. The high H2 concentrations in the steam in this part of the Sveifluháls area are indica- tive of a primary upflow zone. An outflow of boiling water from that zone could generate the steam emerging around the ridge of Sveifluháls to the west. Such an outflow, if it exists, must be at close to 1000 m depth as deduced from the subsurface temperatures for the fuma- role steam at Sveifluháls. A drillhole has been sunk to about 800 m depth at the southern shore of Lake Kleifar- vatn. Its bottom temperature is 153°C. Apparently, this hole is not sufficiently deep to reach the presumed lat- eral flow of boiling water. The Vesturháls Area Relatively few samples are available from this area (Tables 1 and 2) which is due to difficult sampling condi- tions rather than scarcity of fumaroles. Around Trölla- dyngja subsurface temperatures obtained by all the gas geothermometers lie in the range 195-297°C. The lowest value of 195°C, which is from a gas sample from Sog (no. 45, Table 5) and based on the C02/N2 geothermometer, is probably low because of atmospheric contamination in the sample. Eliminating this value, the average of all the geothermometry temperatures around Trölladyngja in the Vesturháls area is 256°C. A temperature of 262°C has been measured in 830 m deep drillhole at Trölla- dyngja (Arnórsson etal., 1975a). The geothermometers of D’Amore and Panichi (1980) and Nehring and D’A- more (1984) give similar temperatures for the Trölla- dyngja area samples as the geothermometers of Arnórs- son and Gunnlaugsson (1985). As previously mentioned the water salinity in the well at Trölladyngja suggests that the mineral buffer controlling H2S and H2 concen- trations in the reservoir include magnetite and pyrite. This explains why all the gas geothermometers give temperatures within a reasonable range. The fumarole at Hverinn Eini contains the highest concentrations of C02 and H2S of all samples collected from the Krísuvík field (Table 1). At the turn of the last century this was a very strong fumarole and could be seen from Reykjavík at a distance of about 30 km (Tho- roddsen 1925). Now the fumarole is almost extinct. As deduced from the elevated N2 concentrations and the high N2/Ar ratio the sample is atmoshperically contam- inated making it difficult to estimate with confidence the amount of steam condensation in the upflow. However, bringing N2/Ar ratios to 57.2 (sample 23) would only raise N2 to a total of some 5 mmoles/kg. Thus, it seems evident that much condensation has occurred although the values reported in Table 4 are regarded too high. It is not known what the salinity of the water is in the reservoir below Hverinn Eini. The figures for the H2S, H2 and C02/H2 geothermometers in Table 4 assumed dilute waters. Assuming, on the other hand, saline wa- ters gives temperatures which are higher by 35°, 49° and 108°C, respectively. Using the Zb value for condensation in Table 4 (98%) and the geothermometry functions corresponding with dilute waters gives C02, H2S, and H2 temperatures as follows: 195°, 187° and 182°C. This cor- responds well with the COz/H2 temperature. The limited and apparently inconsistent data for Hverinn Eini can be explained equally well in two ways: 1) Condensation is very extensive in the upflow, the reservoir water is dilute and its temperature is 180-200°C. 2) Condensation is not so extreme in the upflow. The reservoir water is suffi- ciently saline to equilibrate with magnetite rather than pyrrhotite and its temperature is around 300°C. SUMMARY AND CONCLUSIONS The concentrations of C02, H2S, H2, CH4, N2 and Ar in fumarole steam all provide useful information to de- lineate the characteristics of the Krísuvík geothermal reservoir including: 1) Subsurface temperatures. 2) Steam condensation in the upflow. 3) Boiling and partial degassing at high temper- atures. 4) Presence of equilibrium steam in the reservoir. The Krísuvík geothermal field probably represents two hydrothermal systems, one underlying Sveifluháls and the other underlying Vesturháls. In the Sveifluháls area gas geothermometry indicates temperatures of at least 280°C but they seem to be lower, may be about 260°C, around Trölladyngja in the Vesturháls area. At Hverinn Eini, also in the Vesturháls area, subsurface temperatures might be as high as 300°C. Boiling is exten- sive in the upflow and steam condensation relatively limited (0-30%). 45
Síða 1
Síða 2
Síða 3
Síða 4
Síða 5
Síða 6
Síða 7
Síða 8
Síða 9
Síða 10
Síða 11
Síða 12
Síða 13
Síða 14
Síða 15
Síða 16
Síða 17
Síða 18
Síða 19
Síða 20
Síða 21
Síða 22
Síða 23
Síða 24
Síða 25
Síða 26
Síða 27
Síða 28
Síða 29
Síða 30
Síða 31
Síða 32
Síða 33
Síða 34
Síða 35
Síða 36
Síða 37
Síða 38
Síða 39
Síða 40
Síða 41
Síða 42
Síða 43
Síða 44
Síða 45
Síða 46
Síða 47
Síða 48
Síða 49
Síða 50
Síða 51
Síða 52
Síða 53
Síða 54
Síða 55
Síða 56
Síða 57
Síða 58
Síða 59
Síða 60
Síða 61
Síða 62
Síða 63
Síða 64
Síða 65
Síða 66
Síða 67
Síða 68
Síða 69
Síða 70
Síða 71
Síða 72
Síða 73
Síða 74
Síða 75
Síða 76
Síða 77
Síða 78
Síða 79
Síða 80
Síða 81
Síða 82
Síða 83
Síða 84
Síða 85
Síða 86
Síða 87
Síða 88
Síða 89
Síða 90
Síða 91
Síða 92
Síða 93
Síða 94
Síða 95
Síða 96
Síða 97
Síða 98
Síða 99
Síða 100
Síða 101
Síða 102
Síða 103
Síða 104
Síða 105
Síða 106
Síða 107
Síða 108
Síða 109
Síða 110
Síða 111
Síða 112
Síða 113
Síða 114
Síða 115
Síða 116

x

Jökull

Beinleiðis leinki

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.