Jökull


Jökull - 01.12.1987, Síða 41

Jökull - 01.12.1987, Síða 41
mean annual temperature in Krísuvík) the value taken by F is 4.03. The values of N2 c and Zb can obtained by a common solution of equations (1), (11) and (14) using the mea- sured nitrogen (N2 m) and carbon dioxide concentrations in the steam. Results for the Krísuvík field The amount of steam condensation in the upflow of the Krísuvík field has been estimated by the two meth- ods just described (Table 4, Fig. 5). The results indicate relatively limited condensation for the majority of the samples; less than 50% and 30% in the case of conduc- tive heat loss and mixing with cold water, respectively. Estimation assuming conductive heat loss always gives higher values. This is so because the other model, in- volving condensation in cold water, accounts for some of the N2 in the steam sample by degassing of this cold water. Atmospheric contamination causes values for calcu- lated condensation to be too high. Such is clearly the case for samples 7, 8 and 23 in Table 4 as deduced from the elevated N2 content together with high N2/Ar ratios. Estimated condensation for some of the samples gives negative values (Table 4). Apart from analytical error which will, of course, contribute this could be due to: (1) TABLE 4. Gas geothermometry results (°C) for fumarole samples from the Krfsuvík field and estimated condensation in the upflow No. C02 co2/n2 h2s h2 co2/h2 FTS DPS h2co l H2SC02 K «b 1 296 (288) 277 278 252 215 391 339 313 320 47 25 2 293 (283) 271 277 246 208 379 333 303 318 51 28 3 296 (294 290 279 259 227 406 352 324 322 22 9 4 291 (292) 295 272 259 232 404 355 322 312 -II -4 5 294 (296) 303 250 196 120 285 233 231 289 -31 -9 6 285 (279) 270 259 249 221 381 338 304 296 3/ 18 7 292 (204) 184 268 257 229 393 339 319 308 95 91 8 294 (267) 248 245 270 248 414 333 341 284 76 60 9 290 (292) 297 253 249 217 393 337 306 291 -21 -/ 10 292 (292) 294 250 249 214 389 329 306 288 -4 -2 11 294 (295) 298 254 244 204 385 326 300 293 -12 -4 12 294 (281) 265 252 245 205 380 317 302 290 60 37 13 292 (283) 270 252 208 144 299 247 247 290 50 2/ 14 293 (290) 286 262 245 206 378 323 301 301 23 10 15 293 (283) 270 257 244 204 377 321 299 296 53 29 16 294 (275) 255 249 246 207 369 302 302 287 70 48 17 295 (295) 296 257 238 193 366 307 291 295 -2 -1 18 297 (270) 247 231 204 130 290 220 243 269 79 61 19 290 (290) 292 257 237 196 369 321 288 295 -4 -2 20 306 (280) 256 247 233 171 338 253 287 287 80 60 21 266 (265) 261 200 193 142 271 231 217 235 10 5 22 285 (263) 242 262 270 266 270 201 232 233 71 50 23 328 (195) 179 298 248 175 " " 323 355 99 98 “Values in brackets represent CO?-temperatures corrected for condensation according to Zk. SGeothermometer of ARNÓRSSON and GUNNLAUGSSON (1985) which assumes Fischer-Tropsch reaction equilibrium. ÖGeothermometer of D'AMORE and PANICHI (1980). ^The and H^S geothermometers of NEHRING and D'AMORE (1984), respectively. YCondensation assuming conductive cool- ing. ^Condensation assuming mixing of 100°C steam with 5°C water contain- ing 0.71 mmoles/kg of N^. -20 O 20 40 60 80 %zb Fig. 5. Flistograms showing calculated amount of steam condensation in the upflow of the Krísuvík field. Mode of condensation: Zc conductive heat loss, Zb mix- ing of steam at 100°C with water at 5°C. — Súlurit sem sýnir reiknaða þéttingu gufu í uppstreymisrásum á Krísu- víkursvœði. Háttur þéttingar: Zc varmatap með leiðni, Zb blöndun 100°C gufu við 5°C vatn. Presence of equilibrium steam in the reservoir fluid that will cause C02 concentrations to be high for its temper- ature and (2) secondary boiling of partly degassed wa- ter. As C02 is more soluble in water than N2, primary boiling involving partial degassing will cause the remain- ing water to attain high C02/N2 ratio for its temperature and, therefore, also steam formed by extensive boiling of this water. Re-equilibration of partly degassed water with respect to C02 would enhance the increase in the C02/N2 ratio. It seems unlikely that equilibrium steam in the reser- voir accounts for the negative Z-values found for some samples. The presence of such steam would tend to cause H2 concentrations in the fumaroles to be high relative to C02 as H2 is considerably less soluble than C02. As indicated by the H2-temperatures in Table 4 such is not the case. Fig. 6A shows how partial degassing of equilibrated reservoir water will affect the C02/N2 temperatures for steam formed by extensive secondary boiling of this water and Figs. 6B and 6C show how the extent of the primary degassing affects values for calculated conden- sation. Degassing in excess of some 50% of the initial N2 leads to strongly negative values, both for Zc and Zb; 39
Síða 1
Síða 2
Síða 3
Síða 4
Síða 5
Síða 6
Síða 7
Síða 8
Síða 9
Síða 10
Síða 11
Síða 12
Síða 13
Síða 14
Síða 15
Síða 16
Síða 17
Síða 18
Síða 19
Síða 20
Síða 21
Síða 22
Síða 23
Síða 24
Síða 25
Síða 26
Síða 27
Síða 28
Síða 29
Síða 30
Síða 31
Síða 32
Síða 33
Síða 34
Síða 35
Síða 36
Síða 37
Síða 38
Síða 39
Síða 40
Síða 41
Síða 42
Síða 43
Síða 44
Síða 45
Síða 46
Síða 47
Síða 48
Síða 49
Síða 50
Síða 51
Síða 52
Síða 53
Síða 54
Síða 55
Síða 56
Síða 57
Síða 58
Síða 59
Síða 60
Síða 61
Síða 62
Síða 63
Síða 64
Síða 65
Síða 66
Síða 67
Síða 68
Síða 69
Síða 70
Síða 71
Síða 72
Síða 73
Síða 74
Síða 75
Síða 76
Síða 77
Síða 78
Síða 79
Síða 80
Síða 81
Síða 82
Síða 83
Síða 84
Síða 85
Síða 86
Síða 87
Síða 88
Síða 89
Síða 90
Síða 91
Síða 92
Síða 93
Síða 94
Síða 95
Síða 96
Síða 97
Síða 98
Síða 99
Síða 100
Síða 101
Síða 102
Síða 103
Síða 104
Síða 105
Síða 106
Síða 107
Síða 108
Síða 109
Síða 110
Síða 111
Síða 112
Síða 113
Síða 114
Síða 115
Síða 116

x

Jökull

Beinleiðis leinki

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.