Evaluating the fire safety performance In order to check the safety in a conservative way, it is necessary to simulate cases when fire safety devices fail or unexpected problems occur. Statistics show that smoke exhaust systems fail to start and to work properly in roughly 20 % of cases. In addition, it often happens that one emergency exit door remains closed. Therefore, the combination of these 2 failures remains a likely scenario which will be simulated. Results from fire simulation As discussed earlier, the main concern for evacuation purposes is the visibility. It is important that it remains above Vrit at z = 2 meters from the floor. In addition, the visibility is also checked at the height of 6 meters for the people standing at the top of the stands. Figure 2 (left) shows the visibility in a cross section containing the fire. It shows a very clear two-layer condition, with fresh air close to the floor and hot smoke above.The visibility remains acceptable after 10 minutes at ground fioor level, but is under critical value at the top of the stand. Figure 2 (right) shows a top view of the visibility at z = 2 meters from the floor shown after 12 minutes. At this time, the visibility is poor mainly on the left side and above the stand. In addition to visibility slices, visibility probes are positioned in the center of the hall and above the stand. They give the time evolution of the visibility at certain heights (see Figure 3), allowing the determination of the time when the visibility becomes critical at z = 2 m and z= 6 m above the floor, shown in Table 1. The visibility is also calculated in the case the smoke exhaust system fails to start and vents do not open. As shown by these results, the visibility becomes critical after 12:30° minutes on the ground floor and after 5:30° minutes at the top of the stands, when the smoke exhaustion system works properly. When the vents remain closed, these critical times fall to 8:30° and Figure 3:Time evolution of the visibility at the center with and without smoke exhaustion system working. 4:40° minutes respectively. Evacuation simulation The fire and smoke spread simulation has allowed the determination of the critical times, when complete evacuation must be achieved. The owner wishes to accept 3500 people on the skating ring (zone 1) and 600 on the first t„i,(min.) Probe position [Visibility <10 m] c E z = 2m,middleofhall 12:30° 01 r- > >< z = 6m, above stand 5:30° 1/1 o P z = 2m,middleofhall 8:30° z S z = 6m, above stand 4:40° Table 1 :Time to critical visibility floor (zone 2). Characteristics of the occupants, such as walking velocity, size and agility are set to be consistent with a young population from 20 to 35 years, who are most likely to attend a rock concert. The time to be aware of the fire t is estimated aw to be 50 sec. and the reaction time t to be 50 reac sec. Therefore, a total response time will be t ' r resp = t + t = 100 sec. aw reac The safety can be assessed by considering the K safe t evac Figure 1: FDS model of Skautahöllin (left). Fire and smoke visualization after 3 minutes (right). factor K ,, defined as the ratio between the evacuation time and the critical time: If K r < 1, the safety level is not sufficient. If Ksafc > 1, the safety level is sufficient. However, it is necessary to consider a certain security delay to take into account unexpected problems such as panic or longer reaction time, and how familiar the occupants are with ... upp í vindinn I 37
Blaðsíða 1
Blaðsíða 2
Blaðsíða 3
Blaðsíða 4
Blaðsíða 5
Blaðsíða 6
Blaðsíða 7
Blaðsíða 8
Blaðsíða 9
Blaðsíða 10
Blaðsíða 11
Blaðsíða 12
Blaðsíða 13
Blaðsíða 14
Blaðsíða 15
Blaðsíða 16
Blaðsíða 17
Blaðsíða 18
Blaðsíða 19
Blaðsíða 20
Blaðsíða 21
Blaðsíða 22
Blaðsíða 23
Blaðsíða 24
Blaðsíða 25
Blaðsíða 26
Blaðsíða 27
Blaðsíða 28
Blaðsíða 29
Blaðsíða 30
Blaðsíða 31
Blaðsíða 32
Blaðsíða 33
Blaðsíða 34
Blaðsíða 35
Blaðsíða 36
Blaðsíða 37
Blaðsíða 38
Blaðsíða 39
Blaðsíða 40
Blaðsíða 41
Blaðsíða 42
Blaðsíða 43
Blaðsíða 44
Blaðsíða 45
Blaðsíða 46
Blaðsíða 47
Blaðsíða 48
Blaðsíða 49
Blaðsíða 50
Blaðsíða 51
Blaðsíða 52
Blaðsíða 53
Blaðsíða 54
Blaðsíða 55
Blaðsíða 56
Blaðsíða 57
Blaðsíða 58
Blaðsíða 59
Blaðsíða 60
Blaðsíða 61
Blaðsíða 62
Blaðsíða 63
Blaðsíða 64
Blaðsíða 65
Blaðsíða 66
Blaðsíða 67
Blaðsíða 68
Blaðsíða 69
Blaðsíða 70
Blaðsíða 71
Blaðsíða 72
Blaðsíða 73
Blaðsíða 74
Blaðsíða 75
Blaðsíða 76
Blaðsíða 77
Blaðsíða 78
Blaðsíða 79
Blaðsíða 80
Blaðsíða 81
Blaðsíða 82
Blaðsíða 83
Blaðsíða 84

x

Upp í vindinn

Beinir tenglar

Ef þú vilt tengja á þennan titil, vinsamlegast notaðu þessa tengla:

Tengja á þennan titil: Upp í vindinn
https://timarit.is/publication/1929

Tengja á þetta tölublað:

Tengja á þessa síðu:

Tengja á þessa grein:

Vinsamlegast ekki tengja beint á myndir eða PDF skjöl á Tímarit.is þar sem slíkar slóðir geta breyst án fyrirvara. Notið slóðirnar hér fyrir ofan til að tengja á vefinn.