Upp í vindinn - 01.05.2009, Side 38

Upp í vindinn - 01.05.2009, Side 38
Evaluating the fire safety performance Case Population Total 1 4200 2 3700 2* 3700 3 2500 3* 2500 Evacuationtime t (min.) evac ' ' 2ndfloor P'floor 3:30°** 7:50° 3:30°** 7:10° 3:30°** 9:20° 3:30°** 5:20° 3:30°** 7:00° 3 vents 2nd floor P'floor 1.57 1.60 1.57 1.74 1.57 1.34 1.57 2.34 1.57 1.79 No vents 2ndf1oor P’floor 1.33 1.09 1.33 1.19 1.33 0.91 1.33 1.59 1.33 1.21 Criticaltimest „ crit 3 vents 5:30° 12:30° Novents 4:40° 8:30° (*) 1 exitblocked (**) estimated time Table 2: Population, evacuation times and safety factors for various configuration cases. the evacuation routes. Therefore, engineers should take a safety factor higher than 1. How high depends mainly on how conservative were the choices made by the engineer for the simulation. The evacuation is simulated for different number of occupants (see Table 2) in zone 1 (see Figure 4), but with fixed number of occupants in Zones 2 and 3 (100 and 600).The corresponding evacuation times are compared to the critical times defined earlier, and K , is calculated. As recommended by guidelines, tests with one of the exit doors blocked are also simulated (case 2* and 3*). The results show that the safety is not sufficient in the worst case (Ksafc = 0.91 < 1) for 3700 people if vents are not functioning and one exit door closed (case 2*). For 2600 people, the safety level is sufficient (K ifc > 1.2), even with the 2 failures in the safety system. Prescriptive based methods based on recommendations from building regulations [9] allow calculating the maximum number of people as a function of the size and number of emergency exits. Applying this method to the skating hall gives a maximum close to 1800 people. Conclusion In this article, we have described the fire safety investigation process for new or existing Figure 4: Evacuation modeling in case 2: population at t= 0 on 1 st (left) and 2nd floor (right). Figure 5 : Evacuation modeling in case 2: population at t= 3 min. on 1 st (left) and 2nd floor (right). building, using both CFD and evacuation models. As an example, the fire safety of the skating hall in Reykjavik is tested in a very different configuration than the intended use was, with a rock concert hosting about 3 times the normal population of the hall. The fire and smoke simulation carried out using the CFD software FDS gave the critical time for evacuation, which was then compared to results from an evacuation model built with BuildingExodus, tested for various populations and exit conditions. It appeared that the evacuation time remained smaller than a critical time based on visibility conditions, showing that both thc smoke exhaustion system in the roof and the emergency routes created a sufficient level of safety in the case safety devices work properly. However, failures must be considered while assessing the safety of a building, and authorities and fire safety engineers should always make conservative choices and carry out sensitivity analysis to account for possible unexpected problems. The performance based evacuation simulation suggested that the level of safety wasn’t sufficient for 3600 people (case 2) in the likely case of 2 failures in the system. The prescriptive method suggested a significantly lower value close to 1800 people, but the safety level for 2600 people (K fc <1.2; lVz minute safety delay) was confirmed to be sufficient considering the conservative choices made during the simulations. REFERENCES [1] Karlsson B., Quintiere J.G. (2000):"Enclosure Fire Dynamics", CRC Press. [2] Drysdale D.D. (1992): "An Introduction to Fire Dynamics", Wiley-lnterscience. [3] SFPE Handbook of Fire Protection Engineering, 2nd ed. (1995): National Fire Protection Association. [4] Fire Dynamic Simulator FDS and Smokeview homepage: http://www.fire.nist. gov/fds/ [5] BuildingExodus homepage, http://fseg.gre. ac.uk/exodus/ [6] Bryan J.L. (1995):"Behavioral response to fire and smoke", SFPE Handbook of Fire Protection Engineering", 2nd ed., National Fire Protection Association. [7] PaulsJ.(1995):"Movementof people",SFPE > Handbook of Fire Protection Engineering", 2nd ed„ National Fire Protection Association. [8] Nelson H.E, MacLennan H.A. (1995): "Emergency movement", SFPE Handbook of Fire Protection Engineering" 2nd ed., National Fire Protection Association. [9] Byggingarreglugerð 441/1998. 38 I ... upp í vindinn

x

Upp í vindinn

Direkte link

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Upp í vindinn
https://timarit.is/publication/1929

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.