Jökull


Jökull - 01.12.1982, Side 25

Jökull - 01.12.1982, Side 25
mostly volcanic tufFs. According to seismic results of Palmason (1971), the total integrated thicknessofthe flood basalt formation varies from 3 to 9 kilometers. The basalt plateau is heavily eroded, faulted, in- truded by a number of central volcano structures and transsected by an enormous number of basaltic dikes. Dense swarms ofdikes radiatingout from the volcano cores are a frequent occurrence. Although the hydrological properties of the plat- eau are not well known, a few main features appear quite clear. There is concentrated horizontal per- meability or íluid conductivity along many contacts of lava beds and/or tuffs. The bulk of the individual lava beds is, on the other hand, apparently ofa very low conductivity. Concentrated vertical fluid con- ductivity is mainly up along the walls of dikes or possibly through dikes of a sufficiently open colum- nar structure. The role of faults is much less clear. I he open interbed contacts and the open dikes thus appear to be the major fluid conductors of the flood basalt series. Superimposed on the system of major conductors there may be a more dispersed fluid conductivity through smaller fractures and openings. Little is known about this type of conductivity, and it appears to be of less importance for the develop- ment ofgeothermal systems. To attempt at quantifying rock/water heat trans- fer in the above scenario, it is useful to introduce typical idealized fluid conducting elements that can provide simple models of the heat transfer processes m the real situations. In this respect pipe-like and sheet-like elements are of particular interest. The pipe elements carry concentrated currents ofwater with a small cross section over long distances. Many such elements can form pipe-grids. The sheets are fracture type elements having a large rock/water contact area but a very small aperture. Clearly, there can be systems of interconnected sheets form- tng one- or two-dimensional networks. Moreover, the orientation of sheets is important. Open forma- tion contacts generate horizontal flow-sheets while openings along the walls of dikes represent vertical flow sheets. Of particular interest is that the latter type of sheets can harbor convective íluid move- ments that transfer heat vertically up. The cooling of the formations at the lower end leads to thermo- elastic contraction that increases the local aperture and opens up new fracture space. The open vertical flow sheet can thus migrate downward by such a process that we shall refer to as convective down- ward migration (CDM). The process has been dis- cussed elsewhere by the present writer (Bodvarsson 1979, 1982a) and involves concepts that have been advanced earlier by Bodvarsson (1951), Palmason (1976), White (1968), Bodvarsson and Lowell (1972) and Lister (1972, 1974, 1976). The heat transfer in the above type of elements will now be discussed in little more detail. Thesinglepipe. The pipe-like conductors represent the simplest case. Although a variety of irregular cross section can be envisioned, rather elementary potential theoretical arguments indicate that on a sufficiently long time scale, apipe afany meaningful cross section can be approximated by a pipe of a circular cross section with a properly chosen equi- valent diameter d. Since a discussion of the argu- ments involved would not be too useful here, we will refrain from entering into details. Consider now a horizontal pipe of diameter d that is buried at a depth D below the surface ofa homo- genous/isotropic half-spaceofthermal conductivity k and dilfusivity a. Let the temperature of the half- space away from the pipe be T and the pipe surface have a temperature zero. An elementary potential theoretical argument shows that in a steady state situation, the rate of heat uptake by conduction per unit length of the pipe is (Bodvarsson 1949) H = 277kT/ln(4D/d) (1) Carslaw and Jaeger (1959) furnish the appropriate relations for a transient situation. Let the pipe be emplaced at time t = 0. For times t in the interval 250 d2/a <t < D2/4a, the rate of heat uptake is approximately H = 4xrkT/ln(1.2N) (2) whereN = 4at/d2 is theFouriernumberofthepipe. Grid ojpipes. The transient heat uptake by a grid of parallel pipesofspacing s that were embedded at time t = 0 in a homogeneous conducting space of initial temperatureThas been discussed by Bodvars- ronand Reislad (1982). In thesamesettingand using the same notation as above, the rate of heat uptake per unit length of each pipe is given by H = T/R ' (3) where R is the conduction resistance which for t > 250 d2/a is R = ((7rat)l/2/2ks) + (ln(1.2N)/47Tk). (4) The horizontal sheet in steady state. Let the sheet be buried at a depth D, and, íör convenience, be rec- tangular of dimensions B X L where B>>D, L>>D and have an aperture that is negligible as compared to D. There is a uniform/unidirectional flow of water along L and of magnitude m per unit JÖKULL 32. ÁR 23
Side 1
Side 2
Side 3
Side 4
Side 5
Side 6
Side 7
Side 8
Side 9
Side 10
Side 11
Side 12
Side 13
Side 14
Side 15
Side 16
Side 17
Side 18
Side 19
Side 20
Side 21
Side 22
Side 23
Side 24
Side 25
Side 26
Side 27
Side 28
Side 29
Side 30
Side 31
Side 32
Side 33
Side 34
Side 35
Side 36
Side 37
Side 38
Side 39
Side 40
Side 41
Side 42
Side 43
Side 44
Side 45
Side 46
Side 47
Side 48
Side 49
Side 50
Side 51
Side 52
Side 53
Side 54
Side 55
Side 56
Side 57
Side 58
Side 59
Side 60
Side 61
Side 62
Side 63
Side 64
Side 65
Side 66
Side 67
Side 68
Side 69
Side 70
Side 71
Side 72
Side 73
Side 74
Side 75
Side 76
Side 77
Side 78
Side 79
Side 80
Side 81
Side 82
Side 83
Side 84
Side 85
Side 86
Side 87
Side 88
Side 89
Side 90
Side 91
Side 92
Side 93
Side 94
Side 95
Side 96
Side 97
Side 98
Side 99
Side 100
Side 101
Side 102
Side 103
Side 104
Side 105
Side 106
Side 107
Side 108
Side 109
Side 110
Side 111
Side 112
Side 113
Side 114
Side 115
Side 116
Side 117
Side 118
Side 119
Side 120
Side 121
Side 122
Side 123
Side 124
Side 125
Side 126
Side 127
Side 128
Side 129
Side 130
Side 131
Side 132
Side 133
Side 134

x

Jökull

Direkte link

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.