Jökull


Jökull - 01.12.1961, Side 33

Jökull - 01.12.1961, Side 33
metamorphism. Various invgstigations have indicated that the two types differ mainly in the subsurface temperature and that most other factors can probably be regarded as functions of this quantity. The hot-water areas are characterized by a rela- tively low subsurface temperature, in the upper flood basalts at least. Afost of the areas in the North-West and North appear to have a tem- perature below 100° C. Some of the large hot- water areas in the South-West and the West have temperatures between 100° C and 150° C. The large natural-steam areas, on the other hand, are characterized by subsurface tempera- tures above 200° C. The maximum measured is about 230° C. The thermal areas are preferabiy classified on the basis of the temperature conditions. The hot-water areas are classified as the low-tempera- ture activity and the natural-steam areas as the high-temperature activity. As a matter of course, there are no weli-de- fined limits between the two groups. There is a number of important borderline cases, as can be expected. The classification can be made some- what more quantitative on the basis of the con- cept of the base temperature, which will be dis- cussed below. (b) Magnitude of the therrnal areas. The heat flow to the surface, that is, the heat output of the thermal areas, varies within wide limits. The output of some of the smaliest hot- water areas is only of the order of 105 cal/sec, whereas the largest naturai-steam areas have an output of the order of 10a cal/sec. This great variation suggests the introduction of a scale of magnitude in order to classify the areas with re- garcl to the heat output. On the other hand. the heat output is a figure which in most cases is known with little accuracy and is even sorne- what uncertain by definition. This situation warrants only a scale with relatively wide steps. A scale with three steps appears appropriate. TABLE I. Magnitude. I. II. III. Total Heat Output. 5 — 25 x 10° cal/sec 25 - 125 125 - 750 This scale will be applied mainly to systems of thermal areas, as will be discussed below, where also the various components of the heat output will be discussed in some detail. 31

x

Jökull

Direkte link

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.