TABLE IV Chemical composition of water from steam wells in the Reykjavik, Hengill and Krysuvik areas. Analyses: U.S. Geological Survey, Menlo Park, California. Reykjavik. Hengill. Krysuvik. Spring, Well Well 88° C at Hveragerdi at Seltun Date of collect. 2/10’58 31/8’58 10/9’58 SiO^ ........................... A1 ............................. Fe.............................. Mn.............................. Cu.............................. Pb.............................. Zn.............................. As.............................. Ca.............................. Mg.............................. Na.............................. K............................... Li.............................. NH4 ............................ HCOs ........................... CO3 ............................ SO4 ............................ C1 ............................. F............................... Br.............................. 1............................... N02 ............................ NOs ............................ po4 ............................ B............................... Sulfidcs as H2S ................ Dissolved solids residue at 180° C . . Harness as CaC03 ............... PH ............................. Specific conductance micromhos/cm at 25° C ....................... Tliis procedure is based on the fact that the subsurface chemical and physical conditions appear to change considerably as the base temperature increases beyond 150° G/,' As a matter of course, this is no sharp limit. Data on the measured base temperature in a number of thermal areas are given in TABLES 11 and III. The maximum encoun- tered is about 230° C. 126 ppm 283 ppm 425 0.13 0.37 0.10 0.00 0.12 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.08 0.00 1.90 2.80 8.70 0.30 0.00 0.50 159 174 500 1.40 10 68 0.00 0.10 0.60 0.00 0.10 0.00 24 0.00 43 57 50 17 72 67 30 152 735 1.00 2.10 0.70 0.90 0.50 4.80 0.10 0.00 0.10 0.00 0.00 0.03 0.00 0.00 0.40 0.10 0.08 0.15 0.06 0.83 1.70 0.2 3.20 7.00 285 913 2,030 5 6.2 24 9,40 9,40 9,30 281 941 2,760 (e) The total transport of heat and water. Natural heat escapes from thermal areas in the following ways, (1) as the sensible heat content of hot water and steam issued at the surface, (2) by conduction and radiation from hot ground, (3) by conduction from the channels of flow, and (4) by underground drainage of water. The first two factors appear to predominate. 35
Qupperneq 1
Qupperneq 2
Qupperneq 3
Qupperneq 4
Qupperneq 5
Qupperneq 6
Qupperneq 7
Qupperneq 8
Qupperneq 9
Qupperneq 10
Qupperneq 11
Qupperneq 12
Qupperneq 13
Qupperneq 14
Qupperneq 15
Qupperneq 16
Qupperneq 17
Qupperneq 18
Qupperneq 19
Qupperneq 20
Qupperneq 21
Qupperneq 22
Qupperneq 23
Qupperneq 24
Qupperneq 25
Qupperneq 26
Qupperneq 27
Qupperneq 28
Qupperneq 29
Qupperneq 30
Qupperneq 31
Qupperneq 32
Qupperneq 33
Qupperneq 34
Qupperneq 35
Qupperneq 36
Qupperneq 37
Qupperneq 38
Qupperneq 39
Qupperneq 40
Qupperneq 41
Qupperneq 42
Qupperneq 43
Qupperneq 44
Qupperneq 45
Qupperneq 46
Qupperneq 47
Qupperneq 48
Qupperneq 49
Qupperneq 50
Qupperneq 51
Qupperneq 52
Qupperneq 53
Qupperneq 54
Qupperneq 55
Qupperneq 56
Qupperneq 57
Qupperneq 58
Qupperneq 59
Qupperneq 60
Qupperneq 61
Qupperneq 62
Qupperneq 63
Qupperneq 64
Qupperneq 65
Qupperneq 66
Qupperneq 67
Qupperneq 68

x

Jökull

Direct Links

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.