Fróðskaparrit - 01.01.2002, Side 103

Fróðskaparrit - 01.01.2002, Side 103
ARKTISKA FJALLAVEÐRIÐ í 2000 Á SORNFELLI 101 data are quality controlled and stored in a database. Plots of the most important parameters are shown on the website http://www.metsupport.dk/data/sornfelli. These plots are updated hourly. Data are also published on the website of the Faro- ese Office of Public Works, http://www.lv.fo/egl_en/real_sornf/ sornfnow.html, which also has photographs from the prepa- ration of the site during 1999. The instrument cylinder is continuously monitored by 4 internal temperature sen- sors and 15 other control parameters, en- abling remote inspection of the overall op- eration. Since the start not many data have been lost. This is mainly due to the remote inspection, which enables dealing remotely with issues like turning on more heat in the lid if snow accumulated there, checking the lifting ntechanism, checking that the đrain in the bottom of the cylinder is open, and being able to call for local assistance, sup- plied by LV, and the military personnel at Sornfelli, when needed. Air temperature Four different air temperature values are recorded at the Sornfelli meteorological station. A shielded and an unshielded mean air temperature from the platform sensors (Fig. 5), which are granted 9 minutes for acclimatization, then one minute of record- ing before the platform is lowered into the cylinder. A shielded 30 min mean air tem- perature from the temperature sensor fixed on the external boom (Fig. 5), and a shield- ed I min mean air temperature from the same sensor, recorded during the same minute as the platform sensors record. In the year 2000, one minute mean tem- perature values from all three sensors recorded simultaneously, showed the un- shielded sensor to be warmest, with a MAAT of 2.18°C, while the shielded sen- sor fixed on the boom was coldest with a MAAT of 1.76°C. The shielded sensor on the platform had a MAAT of 1,83°C. These three measurements are combined into one corrected annual air temperature (Fig. 6) using the following two rules: 1) Use the coldest sensor. 2) Use data from the coldest platform sensor, if the shielded fíxed sensor is in the interval +0.2°C to -0.8°C. The first rule both prevents the use of data from the shielded platform sensor, when it is not sufficiently cooled in calm weather, and generally prevents the use of data from the unshielded sensor. The sec- ond rule prevents using the fixed sensor, when icing keeps the temperature stable during freezing or thawing. Using these simple rules the shielded platform sensor contributed 61 % to the data of the corrected air temperature in 2000, while 37% came from the fixed outside sensor, and only 2% from the unshielded platform sensor. The corrected air tempera- ture (Fig. 6) for year 2000 has a MAAT of only 1.71°C. The annual amplitude was only 8.7°C (Table 2), based on monthly val- ues. The warmest month was August with 6.5°C, while April was coldest with -2.2°C (Table 2). Analysing the distribution of data used from the different sensors for the con- structed air temperature curve, shows that the unshielded sensor was used only during calm nights, when both of the shielded sen-
Side 1
Side 2
Side 3
Side 4
Side 5
Side 6
Side 7
Side 8
Side 9
Side 10
Side 11
Side 12
Side 13
Side 14
Side 15
Side 16
Side 17
Side 18
Side 19
Side 20
Side 21
Side 22
Side 23
Side 24
Side 25
Side 26
Side 27
Side 28
Side 29
Side 30
Side 31
Side 32
Side 33
Side 34
Side 35
Side 36
Side 37
Side 38
Side 39
Side 40
Side 41
Side 42
Side 43
Side 44
Side 45
Side 46
Side 47
Side 48
Side 49
Side 50
Side 51
Side 52
Side 53
Side 54
Side 55
Side 56
Side 57
Side 58
Side 59
Side 60
Side 61
Side 62
Side 63
Side 64
Side 65
Side 66
Side 67
Side 68
Side 69
Side 70
Side 71
Side 72
Side 73
Side 74
Side 75
Side 76
Side 77
Side 78
Side 79
Side 80
Side 81
Side 82
Side 83
Side 84
Side 85
Side 86
Side 87
Side 88
Side 89
Side 90
Side 91
Side 92
Side 93
Side 94
Side 95
Side 96
Side 97
Side 98
Side 99
Side 100
Side 101
Side 102
Side 103
Side 104
Side 105
Side 106
Side 107
Side 108
Side 109
Side 110
Side 111
Side 112
Side 113
Side 114
Side 115
Side 116
Side 117
Side 118
Side 119
Side 120
Side 121
Side 122
Side 123
Side 124
Side 125
Side 126
Side 127
Side 128
Side 129
Side 130
Side 131
Side 132
Side 133
Side 134
Side 135
Side 136
Side 137
Side 138
Side 139
Side 140
Side 141
Side 142
Side 143
Side 144
Side 145
Side 146
Side 147
Side 148
Side 149
Side 150
Side 151
Side 152
Side 153
Side 154
Side 155
Side 156
Side 157
Side 158
Side 159
Side 160
Side 161
Side 162
Side 163
Side 164
Side 165
Side 166
Side 167
Side 168
Side 169
Side 170
Side 171
Side 172

x

Fróðskaparrit

Direkte link

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Fróðskaparrit
https://timarit.is/publication/15

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.