Jökull


Jökull - 01.01.2015, Síða 45

Jökull - 01.01.2015, Síða 45
Grain characteristics of tephra from Katla and Hekla eruptions more slowly and travel further through the air than larger grains with more rounded shape and uneven surface. Walker et al. (1971) found that down to a diameter of 1 mm cylinders have lower terminal ve- locity than spheres. Here this seems also to be the case for grains smaller than 1 mm. When looking at the differences in grain shape as seen in the SEM (Figures 9 and 13) the needle- or rod- like grains that characterize the SILK-LN tephra are almost completely missing in the Hekla 1947 tephra where equant grains are most common. Another dif- ference is that grains with smooth, fluidal surface are much more common in the Hekla tephra than in the SILK-LN tephra. The main difference between the silicic Katla tephra SILK-LN and the Hekla 1947 tephra regard- ing grain morphology can be summed up in the fol- lowing way. The grains of the SILK-LN tephra are significantly more elongated than those of the Hekla 1947 tephra but the ruggedness appears to be simi- lar. According to Eiríksson and Wigum (1989) grains from silicic magma are readily more elongated than the basaltic ones and magmatic grains tend to be more elongated than the hydromagmatic grains. Accord- ing to the elongation values (see Tables 1 and 2) the SILK grains are very elongated which fits the descrip- tion above regarding viscous silicic magma producing more elongated grains. The elongated SILK-LN grain shape is here believed to connect to the phreatomag- matic explosive activity. It is suggested that the reason for the very elongate shape is the break-up of viscous silicic magma with abundant elongate vesicles as a re- sult of a shock caused either by cooling contraction, a sudden expansion of steam, or both. Both the Hekla and Katla tephra grains become less rugged with dis- tance from source. The Katla tephra becomes more elongated farther from source, contrary to the Hekla tephra that becomes more circular farther from source. One reason for this difference could be the deficiency of elongated grains in the Hekla tephra. Potential effects of fine tephra on health and avia- tion The grain size data represents material deposited ter- restrially, on the ground, and therefore gives min- imum values for the amount of material that was erupted, in particular for material ≤4Φ (≤0.063 mm) that can travel over long distances, as exemplified by the Hekla 1947 tephra deposited in Finland with grain size of 3 to 15µm (0.003–0.015 mm, Salmi, 1948) and the Eyjafjallajökull 2010 tephra (Gudmundsson et al., 2012). Most samples from the SILK-LN tephra are considered representative of what was deposited (with one or two exceptions). The Hekla 1947 tephra samples of Thorarinsson (1954) are considered repre- sentative, the Hekla samples collected in 2013 less so. The data shows that silicic Katla eruptions pro- duce greater quantities of material ≤4 Φ (≤0.063 mm) than Hekla eruptions of similar composition and are therefore more likely to affect air traffic and the health of people. These small grain sizes can reach up to the stratosphere where air traffic takes place. The air must not contain more than 4 mg of tephra per m3 for air traffic to be safe (EASA Safety Information Bulletin, 2013). At distances of 65–70 km from source the pro- portion of deposited material ≤4 Φ (≤0.063 mm) was up to 42 Wt% and 33 Wt% for Katla and Hekla tephra, respectively. In case of the SILK-LN tephra the data shows that grains equal and smaller than 6.5 Φ (0.011 mm or 11 µm) were present in amounts greater than 1-8 Wt% at distances of 65 km. These grains are breathable, i.e. can be inhaled. The elongate shape of the grains could be of concern because fibrous material, with length- diameter ratio of 3, can be hazardous when the fibers are longer than 5 µm (Horwell and Baxter, 2006). Checking for the presence of such very small grains will have to be subject of another study. SUMMARY The SILK-LN tephra • During the course of the eruption the SILK-LN tephra tends to get more coarse-grained and the Wt% of the fine-grained tephra decreases sig- nificantly with time. • The SILK-LN tephra becomes gradually more fine-grained away from the source. The mean grain size (bulk samples) changes from 0.23 mm (2.12 Φ) at 22 km to 0.13 mm (2.94 Φ) at 65 km. JÖKULL No. 65, 2015 45
Síða 1
Síða 2
Síða 3
Síða 4
Síða 5
Síða 6
Síða 7
Síða 8
Síða 9
Síða 10
Síða 11
Síða 12
Síða 13
Síða 14
Síða 15
Síða 16
Síða 17
Síða 18
Síða 19
Síða 20
Síða 21
Síða 22
Síða 23
Síða 24
Síða 25
Síða 26
Síða 27
Síða 28
Síða 29
Síða 30
Síða 31
Síða 32
Síða 33
Síða 34
Síða 35
Síða 36
Síða 37
Síða 38
Síða 39
Síða 40
Síða 41
Síða 42
Síða 43
Síða 44
Síða 45
Síða 46
Síða 47
Síða 48
Síða 49
Síða 50
Síða 51
Síða 52
Síða 53
Síða 54
Síða 55
Síða 56
Síða 57
Síða 58
Síða 59
Síða 60
Síða 61
Síða 62
Síða 63
Síða 64
Síða 65
Síða 66
Síða 67
Síða 68
Síða 69
Síða 70
Síða 71
Síða 72
Síða 73
Síða 74
Síða 75
Síða 76
Síða 77
Síða 78
Síða 79
Síða 80
Síða 81
Síða 82
Síða 83
Síða 84
Síða 85
Síða 86
Síða 87
Síða 88
Síða 89
Síða 90
Síða 91
Síða 92
Síða 93
Síða 94
Síða 95
Síða 96
Síða 97
Síða 98
Síða 99
Síða 100
Síða 101
Síða 102
Síða 103
Síða 104
Síða 105
Síða 106
Síða 107
Síða 108
Síða 109
Síða 110
Síða 111
Síða 112
Síða 113
Síða 114
Síða 115
Síða 116
Síða 117
Síða 118
Síða 119
Síða 120

x

Jökull

Beinleiðis leinki

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.