Jökull


Jökull - 01.12.1990, Síða 106

Jökull - 01.12.1990, Síða 106
in Figs. lb to lf. The greatest uncertainty is probably in the prediction of the excess S042- and Ca2+ as discussed above. METHODS Snow cores were collected from the westem part of the Vatnajökull glacier during the spring expedition of the Icelandic Glaciological Society, 1988. The drill sites were located on the glacier by the Loran-C loca- tion system. The Loran-C coordinates are converted to conformal conic Lambert coordinates. The locations close to the Grímsvötn area (cores 1, 2 and 3, Table I) are corrected by moving them 340 m to the west but others are moved 340 m to the west and 80 m to the north (Fig. 2 and Tables I, II and III). This is done to compensate for the local effect of the Grímsvötn area on the Loran-C signals (Fig. 2). Experience has shown this to be the appropriate correction (Finnur Pálsson and Helgi Björnsson, 1990, pers.comm.). The eleva- tion of the drill holes is calculated from their location using the digitizedmaps of Bjömsson (1988) for cores 4 to 9 (Fig. 2, samples 4.1 to 9.1 in Table I) and un- published digitized maps (Helgi Bjömsson and Finnur Pálsson, 1990, pers. comm.) forcores 1 and 3 (Fig. 2, sample 1.1,1.2,1.1,1.2,1.3.. etc, 3.1 and3.2, Tables I and II). The elevation of core 2 (Fig. 2, sample 2.0 and 2.1,2.2.. etc. inTable I andlll) is obtained by a level- ling measurement to a permanent bench-mark on the Grímsfjall mountain (Fig. 2, Theódór Theódórsson, 1990, pers. comm.). The snow cores were collected by PICO lightweight hand coring auger. The core barrel, ex- tensions and T-handle are made of fiber glass but fit- tings, adapters and cutting head are machined from aluminum (Koci, 1983). Drilling through the 1987- 1988 precipitation layer was carried out in several steps. The auger cuts through 50 cm up to a me- ter each time, it is then extracted from the hole and the core and snow-cuttings placed on a core-shaped polyethylene platter (Fig. 3). The snow-cuttings are discharged, the length of the core measured and the integrated core length compared with the down hole logging. The snow in the first meter of the core is compressed during coring, causing the measured core length to be shorter than the hole depth. This discrep- ancy is corrected for by lowering the integrated core by the amount of the snow compression in the first meter (Figs. 4, 5, and 6). Thus, the cores are shown to start at 10 to 30 cm depth in the drillholes in Figs. 4, 5, and 6, but it is important to note that the cores are taken from the surface and down (Tables I, II and III). Each 25 cm part of the core is split into two. One half is placed in a 1 liter polyethylene sample container but the other, which at the end of coring represents the integrated core, is placed in a 6 liter polyethylene bucket. The 25 cm sample is taken for studying down- hole core changes but the integrated sample to study spatial changes in the snow chemistry on the glacier. From cores 3 to 9 only integrated samples were taken (Table I). After the expedition, the samples were melted in the laboratory. This occurs upon storage for up to a week at room temperature. After melting, about 50 ml of each sample were used to obtain the pH of the melt- water, but the rest filtered through a 0.1 prn pore size filter and placed in prewashed low density polyethy- lene plastic bottles. The analytical methods and the average relative analytical errors obtained from dupli- cate determinations are shown in Table IV. The rela- tive error shown in Table IV for Cl“ and S042- is the maximum difference between two of up to 16 repli- cates. The relative error is high reflecting the low concentration of the ions and that the measurements are done close to the detection limits formost methods. The eluant for the determination of Cl_ and S042- is potassiumhydrogenphtalate (1.25 g/1). The pH of the eluant is adjusted to 4.33 by 0.1 M potassium hydrox- ide. Before sample injection, a concentrated eluant is added to the samples in order to compensate for sample effect on the spectra. A relatively large sam- ple loop (500 //1) is used to enhance the sensitivity of the method. The eluant used for the measurement of sodium and potassium ions is deionized water with pH adjusted to 4.5 by purified nitric acid and samples are treated as described above for chloride and sulfate. The analytical results are tested using charge balance equations (1) and (2). The concentration of bicarbonate is calculated at 22 °C from the measured pH assuming the partial pressure of CO2 to be 10-3 5 bar using the equilibrium 102 JÖKULL, No. 40, 1990
Síða 1
Síða 2
Síða 3
Síða 4
Síða 5
Síða 6
Síða 7
Síða 8
Síða 9
Síða 10
Síða 11
Síða 12
Síða 13
Síða 14
Síða 15
Síða 16
Síða 17
Síða 18
Síða 19
Síða 20
Síða 21
Síða 22
Síða 23
Síða 24
Síða 25
Síða 26
Síða 27
Síða 28
Síða 29
Síða 30
Síða 31
Síða 32
Síða 33
Síða 34
Síða 35
Síða 36
Síða 37
Síða 38
Síða 39
Síða 40
Síða 41
Síða 42
Síða 43
Síða 44
Síða 45
Síða 46
Síða 47
Síða 48
Síða 49
Síða 50
Síða 51
Síða 52
Síða 53
Síða 54
Síða 55
Síða 56
Síða 57
Síða 58
Síða 59
Síða 60
Síða 61
Síða 62
Síða 63
Síða 64
Síða 65
Síða 66
Síða 67
Síða 68
Síða 69
Síða 70
Síða 71
Síða 72
Síða 73
Síða 74
Síða 75
Síða 76
Síða 77
Síða 78
Síða 79
Síða 80
Síða 81
Síða 82
Síða 83
Síða 84
Síða 85
Síða 86
Síða 87
Síða 88
Síða 89
Síða 90
Síða 91
Síða 92
Síða 93
Síða 94
Síða 95
Síða 96
Síða 97
Síða 98
Síða 99
Síða 100
Síða 101
Síða 102
Síða 103
Síða 104
Síða 105
Síða 106
Síða 107
Síða 108
Síða 109
Síða 110
Síða 111
Síða 112
Síða 113
Síða 114
Síða 115
Síða 116
Síða 117
Síða 118
Síða 119
Síða 120
Síða 121
Síða 122
Síða 123
Síða 124
Síða 125
Síða 126
Síða 127
Síða 128
Síða 129
Síða 130
Síða 131
Síða 132
Síða 133
Síða 134
Síða 135
Síða 136
Síða 137
Síða 138
Síða 139
Síða 140
Síða 141
Síða 142
Síða 143
Síða 144
Síða 145
Síða 146
Síða 147
Síða 148
Síða 149
Síða 150
Síða 151
Síða 152
Síða 153
Síða 154
Síða 155
Síða 156
Síða 157
Síða 158
Síða 159
Síða 160
Síða 161
Síða 162
Síða 163
Síða 164
Síða 165
Síða 166
Síða 167
Síða 168
Síða 169
Síða 170
Síða 171
Síða 172
Síða 173
Síða 174
Síða 175
Síða 176
Síða 177
Síða 178
Síða 179
Síða 180
Síða 181
Síða 182
Síða 183
Síða 184
Síða 185
Síða 186
Síða 187
Síða 188
Síða 189
Síða 190
Síða 191
Síða 192
Síða 193
Síða 194
Síða 195
Síða 196
Síða 197
Síða 198
Síða 199
Síða 200
Síða 201
Síða 202
Síða 203
Síða 204
Síða 205
Síða 206

x

Jökull

Beinleiðis leinki

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.