Árbók VFÍ - 01.01.1992, Blaðsíða 193
Nýr ammoníakgeymir 191
[5] Byrne, J.R., Moir, F.E., Williams, R.D, „Stress Corrosion in a 12.000 Tonnes Fully
Refrigerated Ammonia Storage Tank“, Prepared for the 1988 Ammonia Symposium
Safety plants and related facilities, American Institute of Chemical Engineers,
Denver, Colorado August 1988.
[6] New Zealand National Society for Earthquake Engineering, „Seismic Design of Storage
Tanks“, Recommendations of a Study Group of The New Zealand Society for
Earthquake Engineering, December, 1986.
17) Sólnes, J„ „The Seismicity and Earthquake JJazard in Iceland“, University of Iceland,
Engineering Research Institute, Report no. 85008, 1985.
[8] Sigbjörnsson, R„ Snæbjörnsson, J„ „Um jarðskjálftaöryggi ammoníakgeymis",
Verkfræðistofnun Háskóla íslands, 1987.
[9| Uniform Building Code, Part V, „Engineering Regulations-Quality and Design of the
Materials of Construction", Chapter 23.
[ 10] Deutsche Normen, „DIN 4119, Oberirdische zylindrische Flachboden Tankbauwerke aus
metallischen Werkstoffen, Grundlagen, Ausfuhrung, Prufungen.“
[ 111 American National Standards Institute, „ANSI K61.1, safety requirements for the
storage and handling of anhydrous anrmonia", 1981.
[ 12) Slack, A.V., James,G.R„ (editors), „Ammonia, fertilizer science and technology series -
volume 2“, 1979.
113] International Fertilizer Association, „Safety Recommendations for the Large Scale
Storage of Anhydrous Ammonia“,Working document, revision 10, 1984.
[14J Imperial Chemical Industries Limited, „Anhydrous Ammonia, Safe handling of Bulk
Liquid Supplies", Ref. no AG/A1265, 1973.
[15] Chemical Industries Association, „Code of Practice for the Large Scale Storage of Fully
Refrigerated Anhydrous Ammonia in the United Kingdom", 1975.
[16] Imperial Chemical Industries Limited, „Liquid Anhydrous Ammonia, Handling and
Storage“, Ref. no AG/A805.
[ 17[ Hale, C.C., „1983 Survey of Refrigerated Ammonia Storage in the United States and
Canada“, Plant/Operations Progress (Vol. 3, No. 3)
[18] Hale, C.C., „Refrigerated Ammonia Storage: Design and Practice“.
[19] Öystese, H„ „Minutes of Meeting, Supra Landskrona - 19.10.89, with representatives
from Azotas, Jonava, Lithuania“.
120] DIF, Selskabel for riskvurdering, „Failure of the Refrigerated Liquid Ammonia Storage
Tank /Chemical Complex, Ionava, „AZOT“