Jökull


Jökull - 31.12.2001, Side 47

Jökull - 31.12.2001, Side 47
Seismic monitoring during a wastewater injection experiment in Svartsengi system has a transecting fissure swarm which ex- tends about 9 km offshore, along the Reykjanes ridge (Sigurgeirsson, 1995). The Svartsengi field lies at the junction of a small NE-SW striking rift valley and the RSZ. The Svartsengi and Eldvörp geothermal systems are linked as fluid pressure variations in the Svarts- engi field have affected the Eldvörp field, 6km to the west (Björnsson and Steingrímsson, 1991). Figure 1. Seismicity on the Reykjanes Peninsula in 1993. A broken line shows the location of the plate boundary. Seismic stations in operation during June- August are denoted by black triangles in the mid- dle figure. Fissure swarms are shaded. The loca- tion of the Reykjanes (R), Eldvörp (E), Svartsengi (S), and Krýsuvík (K) high-temperature geothermal fields are also shown. The inset shows the location of the Reykjanes Peninsula within Iceland. The earthquakes (denoted by black circles) have a location error of 3 km or less, according to the SIL-network of the Me- teorological Institute of Iceland. The largest event reached M=3.6. The eastern earthquake cluster is as- sociated with the Krýsuvík geothermal area and adja- cent fissures. No surface geothermal activity is visible at the mountain Fagradalsfjall (F) where the western earthquake cluster originated in a single NS-trending swarm, on September 18-19. - Jarðskjálftar (svartir deplar) á Reykjanesskaga árið 1993 samkvœmt SIL- staðsetningarkerfi Veðurstofu Islands. Stœrsti skjálft- inn var 3,6stig á Richterskvarða. Ovissa í skjálfta- staðsetningum er innan við 3 km en engir þeirra höfðu upptök í jarðhitasvœðinu í Svartsengi. Brotna línan táknar plötuskilin. Þau liggja þvert yfir eldstöðva- kerfin (skyggðu svœðin). Helstu jarðhitasvœði eru Reykjanes (R), Eldvörp (E), Svartsengi (S) og Krýsu- vík (K). Svartir þríhyrningar á miðmyndinni tákna staðsetningar fœranlegra jarðskjálftamœla sem rekn- ir voru í Svartsengi í júní, júlí og ágúst, 1993. A geothermal power plant has been in operation in Svartsengi since 1976 (Figure 2). The exploita- tion of geothermal fluids has caused more than 20 bar pressure drawdown within the wellfield (Vatnaskil, 2002) and a cumulative surface subsidence of 237 mm during 1976-1999 (Eysteinsson, 2000). As contin- ued drawdown may diminish the wellfield productiv- ity an injection of wastefluids (70-80°C) has been car- ried out intermittently since 1984. Documented cases of injection-induced earthquakes within geothermal fields (i.e. Batini et al, 1985; Sherburn et al., 1990) prompted the installation of a local seismic monitor- ing network within and around Svartsengi during the 1993 injection experiment, results of which are re- ported here. THE SVARTSENGI GEOTHERMAL FIELD Hyaloclastites and basaltic lavas characterize the Neo- volcanic zones of Iceland. Lithological cross sections from boreholes in geothermal areas consist of alter- nating sections of irregular hyaloclastite masses in between interglacial and postglacial lava sequences. A geological cross section of the Svartsengi field derived from 11 boreholes contains six hyaloclastite units down to 1 lOOm depth (Franzson, 1990). The Svartsengi geothermal system consists of three different aquifer systems. The uppermost aqui- fer (at 30-300 m depth) contains a thin freshwater lens on top of saline groundwater. This aquifer has tem- peratures between 30°C and 100°C and lateral flow towards SW. Beneath it is a steam dominated aquifer which extends to the surface in the easternmost part of the system and a liquid dominated brine water sys- tem with temperatures of 230-240°C below 600 m depth (Björnsson and Steingrímsson, 1991). Hyalo- clastites with low permeability at 300-600 m depth separate the upper-level, warm-water aquifer from the main high-temperature reservoir (Franzson, 1990; Björnsson and Steingrímsson, 1991). Intrusions are found below 800 m depth and dominate the strata from lOOOm to 1400m depth. The main aquifers of the high-temperature system follow NNW-SSE and NE-SW fractures and intrusion boundaries. The av- erage porosity between 400 and 1000 m depth is ap- proximately 10% within the Svartsengi reservoir but around 18% outside the geothermal field (Franzson, 1990). Various geophysical measurements have been made within the wellfield since 1976 for the purpose of monitoring the geothermal exploitation. However, JÖKULL No. 51 45
Side 1
Side 2
Side 3
Side 4
Side 5
Side 6
Side 7
Side 8
Side 9
Side 10
Side 11
Side 12
Side 13
Side 14
Side 15
Side 16
Side 17
Side 18
Side 19
Side 20
Side 21
Side 22
Side 23
Side 24
Side 25
Side 26
Side 27
Side 28
Side 29
Side 30
Side 31
Side 32
Side 33
Side 34
Side 35
Side 36
Side 37
Side 38
Side 39
Side 40
Side 41
Side 42
Side 43
Side 44
Side 45
Side 46
Side 47
Side 48
Side 49
Side 50
Side 51
Side 52
Side 53
Side 54
Side 55
Side 56
Side 57
Side 58
Side 59
Side 60
Side 61
Side 62
Side 63
Side 64
Side 65
Side 66
Side 67
Side 68
Side 69
Side 70
Side 71
Side 72
Side 73
Side 74
Side 75
Side 76
Side 77
Side 78
Side 79
Side 80
Side 81
Side 82
Side 83
Side 84
Side 85
Side 86
Side 87
Side 88
Side 89
Side 90
Side 91
Side 92
Side 93
Side 94
Side 95
Side 96
Side 97
Side 98
Side 99
Side 100
Side 101
Side 102
Side 103
Side 104
Side 105
Side 106
Side 107
Side 108
Side 109
Side 110
Side 111
Side 112
Side 113
Side 114
Side 115
Side 116

x

Jökull

Direkte link

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.