Jökull


Jökull - 31.12.2001, Síða 49

Jökull - 31.12.2001, Síða 49
Seismic monitoring during a wastewater injection experiment in Svartsengi no seismometers were installed in Svartsengi until 1984 when an analog station was established at the southern edge of the geothermal field. Figure 2. A geological map of the Svartsengi geother- mal field showing the location of borholes (black cir- cles), volcanic fissures (thick black lines) and other tectonic lineaments (thinner and dashed lines) vis- ible on top of hyaloclastite hills (white areas) and lavas from shield volcanoes extruding the younger lavafield. The sea is also white. The geothermal field has an elliptical shape and is elongated along the main fault direction (NE-SW) as delineated by the 4 ohmm isoresistivity line at 200 m depth, but seems to be more NNW-SSE oriented at 400 m and 600 m depth. The injection borehole (H-6) is denoted by a star. - Jarðfrœðikort af jarðhitasvœðinu í Svartsengi og ná- grenni þess. Svartur kassi táknar stöðvarhúsið og svartir punktar borholurnar. Niðurdœlingarholan H- 6 er merkt með stjörnu. Efsti hluti jarðhitasvœðisins hefur ellipsulögun eftir meginsprungustefnu svæðis- ins, NA-SV, sbr. 4ohm-metra jafnviðnámslínuna á 200 m dýpi. Þar fyrir neðan virðist jarðhitinn frekar fylgja NNV-SSA lœgari stefnu, efmiðað er við 4 ohm- metra jafnviðnámslínuna á 400-600 m dýpi. Gíga- raðir eru táknaðar með feitum svörtum strikum en mjórri strik sýna aðrar tektónískar línur svæðisins, sem greinilegastar eru á yfirborði eldri jarðmyndana, á móbergshálsum (hvít svæði) og í dyngjuhraunumfrá síðasta hlýskeiði (grá afmörkuð svœði). Hraun eru gráskyggð en hafið hvítt. The exploitation of geothermal fluids from the Svartsengi field has generated more than 20 bar pres- sure drawdown in the wellfield (Björnsson and Stein- grímsson, 1990; Vatnaskil, 2002). The drawdown has probably generated a slight compression of the rock matrix. Levelling and gravity measurements show that an area of lOOkm2 around Svartsengi has sub- sided by 237 mm in a confined region around the well- field (Eysteinsson, 2000). The subsided region has an elliptical shape, being elongated WSW from the Svartsengi wellfield towards the Eldvörp geothermal field and the rate of subsidence seems to be linearly related to well pressure (Eysteinsson, 1993). The pressure drawdown in the geothermal reser- voir has caused some production problems. Wellhead pressures have had to be reduced in order to maintain the flowrate and to diminish calcite scaling within the boreholes. Mass inflow of colder fluids constitutes the greatest potential danger to the geothermal exploita- tion in Svartsengi. The drawdown induced a tempo- rary inflow of colder fluids into the wellfield during March-June 1983 causing a cooling of up to 13°C and a pressure drop up to 5 bars within individual wells (Björnsson and Steingrímsson, 1991). Fortunately, subsequent influxes have all been smaller. The draw- down has a diminishing effect on pore pressure which again increases rock strength within the geothermal reservoir, possibly preventing further inflow of colder fluids. Continued drawdown will lead to decreased pro- ductivity of the wellfield. In order to avert this pro- cess, an injection of wastefluids (70-80°C) has been carried out intermittently since 1984. As a result, the average rate of subsidence within the Svartsengi wellfield decreased from 14mm/year during 1975- 1982 to 7-8 mm/year during 1982-1992 but increased again to 14mm/year during 1992-1999 (Eysteins- sson, 2000). Subsequently, the rate of pressure draw- down decreased from 2.5 bars/year during 1975-1982 to 1.2 bars/year in 1982-1992 (Björnsson and Stein- grímsson, 1991; Eysteinsson 1993). SEISMIC ACTIVITY WITHIN THE SVARTSENGI REGION Persistent microearthquake activity, characterized by both continuous activity and individual swarms, is often found within geothermal regions (Ward et al., 1969; Ward and Björnsson, 1971; Combs and Hadley, 1977; Gilpin and Lee, 1978; Majer and McEvilly, 1979; Foulger, 1988). The spatial distribution of seis- micity within geothermal areas has been used to map the region of natural cooling and thus infer the ex- tent of active heat mining from a geothermal reservoir (Lister, 1974; Foulger et al., 1989). Pressure vari- ations and water level fluctuations are also possible triggers of microearthquake activity within geother- mal reservoirs. JÖKULLNo. 51 47
Síða 1
Síða 2
Síða 3
Síða 4
Síða 5
Síða 6
Síða 7
Síða 8
Síða 9
Síða 10
Síða 11
Síða 12
Síða 13
Síða 14
Síða 15
Síða 16
Síða 17
Síða 18
Síða 19
Síða 20
Síða 21
Síða 22
Síða 23
Síða 24
Síða 25
Síða 26
Síða 27
Síða 28
Síða 29
Síða 30
Síða 31
Síða 32
Síða 33
Síða 34
Síða 35
Síða 36
Síða 37
Síða 38
Síða 39
Síða 40
Síða 41
Síða 42
Síða 43
Síða 44
Síða 45
Síða 46
Síða 47
Síða 48
Síða 49
Síða 50
Síða 51
Síða 52
Síða 53
Síða 54
Síða 55
Síða 56
Síða 57
Síða 58
Síða 59
Síða 60
Síða 61
Síða 62
Síða 63
Síða 64
Síða 65
Síða 66
Síða 67
Síða 68
Síða 69
Síða 70
Síða 71
Síða 72
Síða 73
Síða 74
Síða 75
Síða 76
Síða 77
Síða 78
Síða 79
Síða 80
Síða 81
Síða 82
Síða 83
Síða 84
Síða 85
Síða 86
Síða 87
Síða 88
Síða 89
Síða 90
Síða 91
Síða 92
Síða 93
Síða 94
Síða 95
Síða 96
Síða 97
Síða 98
Síða 99
Síða 100
Síða 101
Síða 102
Síða 103
Síða 104
Síða 105
Síða 106
Síða 107
Síða 108
Síða 109
Síða 110
Síða 111
Síða 112
Síða 113
Síða 114
Síða 115
Síða 116

x

Jökull

Beinleiðis leinki

Hvis du vil linke til denne avis/magasin, skal du bruge disse links:

Link til denne avis/magasin: Jökull
https://timarit.is/publication/1155

Link til dette eksemplar:

Link til denne side:

Link til denne artikel:

Venligst ikke link direkte til billeder eller PDfs på Timarit.is, da sådanne webadresser kan ændres uden advarsel. Brug venligst de angivne webadresser for at linke til sitet.